Do you
know how to configure a storage-area network (SAN) switch?
In this podcast from SearchStorage.co.UK, bureau chief Antony Adshead talks
with Steve Pinder, principal consultant at GlassHouse Technologies (UK), about
how to decide what fabric topology to implement, the importance of zoning and
masking, and how to figure out fan-in and fan-outratios.
·
Internet Explorer: Right Click > Save Target As
·
Firefox: Right Click > Save Link As
What is
involved in configuring a SAN switch?
The
answer to this question depends on whether you're starting a new SAN fabric or
adding a switch to an existing one. If you're starting a new fabric, the
configuration of the switch is much easier. All switches have a default setup
and IP address. You'll need to connect to the IP address using a browser or
command line and carry out some changes on the switch so it's configured
correctly for the environment. For new switches, the only changes you must make
are to configure the IP address, subnet mask and default gateway to allow you
to connect to it via a browser or whatever transport you choose. All the settings
will work for the new fabric.
The first
switch in the fabric is called the principal switch and this switch holds the
master database for fabric configuration. When other switches are added to the
fabric, they download that information from the principal switch. All switches
also have a domain ID which can be statically configured or allocated from the
principal switch.
I tend to
configure switches with static domain IDs so I can guarantee a particular
domain ID will never be allocated to two different switches. If two switches
have been allocated the same ID this could cause fabric segmentation, outages
in the fabric and denial of service tological unit
numbers (LUNs).
For best
practice you should also ensure unused switch ports are disabled. This will
prevent unauthorised devices logging into the fabric and causing disruption to
traffic. This should be done following initial port testing on a switch you're
about to add to the fabric but before you add it to the fabric.
How do I
decide what topology to implement?
Before
starting on SAN topology it's important to say that when redundancy is required
the known best practice is to implement two SAN fabrics and have known devices
connected to both of them. This ensures that if a host is connected to both
fabrics it will still be able to operate effectively if there's a switch, HBA [host bus
adapter] or even an entire fabric failure. In these answers I'm
going to assume that if redundancy is required then two identical SAN fabrics
will be implemented.
There are
a number of topologies that can be used when configuring a fabric, although
there are three I'd recommend, depending on the size of the fabric and number
of switches.
The
single switch fabric has one switch. Director-class
switches can be purchased with hundreds of ports, although
they're expensive compared to low-capacity switches such as those with 32
ports. The single switch SAN offers the lowest possible latency between the
host and its associated storage as all devices are connected to the single
switch.
As most
SANs grow over time, it's more likely that an organisation with a small SAN --
possibly a single switch SAN -- will add more switches as the number of devices
grows. As you add devices this brings us to the second type of SAN, which is a
mesh fabric. This type of fabric is one where every switch in the fabric is
connected to every other switch in the fabric. The connections are via ISLs or
inter-switch links. In this configuration the host will have to go through a
maximum of one ISL to get to the storage it uses. When using a mesh
configuration it's favourable to group a host and its storage on the same
switch so that a host will not have to traverse an ISL to get to its storage.
As the mesh grows, the number of ISLs on a single switch grows at the rate of
one for every additional switch. After a certain point there's little benefit
to adding extra switches as many of the additional ports are required for ISLs.
When you
get to a large number of ports this is where the third type of fabric comes in,
which is called core-edge.
This configuration uses a large switch at the core of the fabric to which you would
generally attach storage. Hosts are attached to smaller edge switches which are
also attached to the core via ISLs. This topology can grow to hundreds or
thousands of ports while ensuring hosts only have to traverse a maximum of two
switches to access storage. Hosts that require very low latency or very high
throughput can be connected to the core.
What is
zoning and masking, and why is it important?
Zoning is
a procedure that takes place on the SAN fabric and ensures devices can only
communicate with those that they need to. Masking takes place on storage arrays
and ensures that only particular World Wide Names [WWNs] can communicate with
LUNs on that array. If the correct masking is applied to the storage array then
there's no absolute necessity to configure zoning on the SAN, although using
zoning and masking is always to be recommended.
There are
two distinct methods of zoning that can be applied to a SAN: World Wide Name
zoning and port zoning.
WWN
zoning groups a number of WWNs in a zone and allows them to communicate with
each other. The switch port that each device is connected to is irrelevant when
WWN zoning is configured. One advantage of this type of zoning is that when a
port is suspected to be faulty a device can be connected to another port
without the need for fabric reconfiguration. A disadvantage is that if an HBA
fails in a server the fabric will need to be reconfigured for the host to reattach
to its storage. WWN zoning is also sometimes called 'soft zoning.'
Port
zoning groups particular ports on a switch or number of switches together,
allowing any device connected to those ports to communicate with each other. An
advantage of port zoning is that you don't need to reconfigure a zone when an
HBA is changed. A disadvantage is that any device can be attached into the zone
and communicate with any device in the zone.
My
opinion is that neither is particularly superior to the other, and what I find
is that the type of zoning used is generally determined by what a particular
consultant or organisation has done in the past.
What do I
need to know about fan-in and fan-out?
The
fan-in ratio denotes the number of hosts connected to a port on a storage
array. There are many methods that have been used to determine the optimum
number of hosts connected to a storage port, but in my experience there are no
hard and fast rules to determine an absolute number.
My
recommendation would always be to assess the throughput of each host you want
to connect to a port, determine the maximum throughput of that port, and add
hosts such that the total throughput is slightly higher than the throughput of
that port. It's very important, however, to ensure you have good utilisation
statistics available to detect any time period where the port is heavily
utilised and could be causing a bottleneck to your SAN fabric.
There are
a number of reasons why it's difficult to give a host count as an optimum fan-out ratio.
These include: differing port speeds -- a 4 Gbps port can obviously handle
twice the throughput of a 2 Gbps port and will allow you to add roughly double
the number of hosts; and multipathing -- if a host has two HBAs, traffic will
either be aggregated down those two HBAs in an active-active mode or all the
traffic will go down one HBA and nothing down the other if the connection is
active-passive.
These
scenarios will have a big impact on how many hosts you can add to a particular
port. In normal operating circumstances, you can connect double the [amount of]
HBAs to a particular port as they will all be doing half the work of the host.
This is in a multipathing environment. If, however, there's an issue with the
SAN and a device has failed over from its active port to its passive port the
remaining ports may be required to carry out twice the standard workload. This
can cause poor performance if you oversubscribe hosts to storage ports.
No comments: